DROP TEST RESULTS OF THE FULL-SCALE CONSTOR® V/TC PROTOTYPE

Year
2007
Author(s)
André Musolff - BAM Federal Institute for Materials Research and Testing
Karsten Müller - BAM Federal Institute for Materials Research and Testing
Martin Neumann - BAM Federal Institute for Materials Research and Testing
Arsène Kadji - BAM Federal Institute for Materials Research and Testing
Bernhard Droste - BAM Federal Institute for Materials Research and Testing
File Attachment
65.pdf567.93 KB
Abstract
In the context of the research on the mechanical safety of packages for radioactive material, fullscale drop tests with spent fuel and HAW transport and storage casks have been performed by the Federal Institute for Materials Research and Testing (BAM). The research reflects national and international interest in acquiring comparative knowledge of full- and reduced-scale model drop tests as well as in Finite Element (FE) calculations. This paper presents the experimental, analytical and first numerical results of the full-scale drop test with the full-scale CONSTOR® V/TC prototype, manufactured by GNS, Gesellschaft für Nuklear-Service mbH, Germany. The prototype was tested by BAM in a 9 m horizontal drop test onto the unyielding target of the BAM drop test facility in Horstwalde, Germany.