Containment Performance of Transportable Storage Casks at 9m Drop Test

Year
2004
Author(s)
Hitoshi TOBITA - HITACHI ZOSEN MECHANICAL CORPORATION
Kenji Araki - Hitachi Zosen Diesel & Engineering Co., Ltd.
File Attachment
Abstract
Spent fuel transportable storage casks usually have a double lid closure system, which consists of primary and secondary lids, and gaskets, to keep the containment function during transportation and storage, and to monitor a leakage or containment function during storage. Metal gasket is planning to be used not only during storage but transportation of both before and after storage. As metal gasket will degrade its containment function by creep during storage period of 50 years, relative displacement such as opening and slide displacement between the flange of the containment vessel and the lid should be restricted to a small range. To maintain the containment performance, we provisionally adopted the maximum opening limit of 0.1mm and the maximum slide displacement limit of 3.0mm in the full-scale cask design based on the report of the fundamental experiment on the metal gasket which examines the relation between leakage rate and sealing gap [1]. The purpose of this study is to analyse the behaviour of the sealed parts (lid & vessel body) under 9m-drop impact test conditions and to establish some analytical method to evaluate this behaviour. In this study, the drop test of 1/3scale model of Hitz-B69 cask with the double lids closure system was carried out, the behaviours of the seal part were measured by