Publication Date
Volume
12
Issue
2
Start Page
39
File Attachment
V-12_2.pdf5.6 MB
Abstract
We discuss methods for the propagation of errors in the determination of plutonium isotopic composition and specific power by gammaray spectroscopy techniques. The 1975 ANSI calorimetry standard is shown to be in error in this regard. The developed formulas are compared with measurements for applicable cases. Some examples of the sensitivity of the specific power to measurement biases are presented.