Year
1981
Abstract
This study demonstrates a feasible way to determine the nuclear material inventory of solvent extraction columns for calculating material balances without process shutdowns. An existing computer code, SEPHIS, was used to calculate the inventories in the solvent extraction cycles of a uranium recovery process. The applicability of the method was tested using published data on the uranium concentration profiles of solvent extraction pulse columns. The application of this method to the extraction cycles of the uranium recovery process is presented for daily uranium loss monitoring over those process units.