RESOLVING MC&A ALARMS FROM PROCESS MONITORING IN A FUEL FABRICATION FACILITY^)

Year
1984
Author(s)
Brian W. Smith - Pacific Northwest National Laboratory
J. Razvi - GA Technologies Inc.
Abstract
Process monitoring data can be used for generating material loss estimates. The intent of using process control data is to enhance nuclear material control and accounting for the timely detection and resolution of discrepancies. The purpose of an alarm resolution system is to distinguish between system errors and an actual loss of nuclear material. A study has been performed to develop and test a site-specific set of alarm resolution procedures. The results of the study are described and include the frequency of alarms, the causes of alarms, the type of resolution, and the modeling of loss estimates.