PROGRESS IN THE DEVELOPMENT OF EXPLOSIVES MATERIALS DETECTORS

Year
1978
Author(s)
W. David Williams - Sandia Laboratories
F. J. Conrad - Sandia Laboratories
T. A. Burrows - Sandia Laboratories
L. L. Sandlin - Sandia Laboratories
Abstract
Five hand-held explosives vapor detectors (Elscint Model EXD-2, ITI Model 70, Leigh-Marsland Model S-201, Pye Dynamics Model PD.2.A, and Xonics Model GC-710) were evaluated for sensitivity to a variety of explosives, iden- tification of false alarm agents, and general performance and maintenance characteristics. The results of this evaluation, as presented, indicate that there is no single explosives detector which is best-suited for use at all nuclear facilities. Rather, there are several site-specific elements which must be considered when choosing an explosives detector. There are several new explosives detector technologies being devel- oped which will out-perform existing commercial equipment. Some of these new detectors may be commercially available by the end of fiscal year 1980 and will be cost-effective to purchase and operate. This paper discusses the following areas of explosives detection research: nitrogen-phosphorous detectors, plas- ma chromatography, mass spectroscopy, small animal olfactory, vapor preconcen- tration, nuclear quadrupole resonance, far infrared radiation imaging, nuclear magnetic resonance, thermal neutron activation, and computerized tomography.