Modular Integrated Monitoring System (MIMS) - Architecture and Implementation

Year
1997
Author(s)
Sharon M. DeLand - Sandia National Laboratories
Donald R. Funkhouser - Sandia National Laboratories
Abstract
The MIMS is being developed as a cost-effective means of performing safeguards in unattended remote monitoring applications. Based on industry standards and an open systems approach, the MIMS architecture supports both data acquisition and data review subsystems. Data includes images as well as discrete and analog sensor outputs. The MIMS uses an Echelon LonWorks network as a standard means and method of data acquisition from the sensor. A common data base not only stores sensor and image data but also provides a structure by which dynamic changes to the sensor system can be reflected in the data acquisition and data review subsystems without affecting the execution software. The architecture includes standards for wide area communications between data acquisition systems and data review systems. Data authentication is provided as an integral part of the design. The MIMS also provides a generic set of tools for analyzing both system behavior and observed events. The MIMS software implements this architecture by combining the use of commercial applications with a set of custom 16 and 32 bit Microsoft Windows applications which are run under Windows NT and Windows 95 operating systems.