REPORT ON FUEL POOL WATER LOSS TESTS

Year
1995
Author(s)
Richard F. Zalenski - West Valley Nuclear Services Company
Abstract
To resolve potential concerns on the integrity of the fuel storage pool at the West Valley Demonstration Project (WVDP), a highly accurate testing technique was developed to quantify water losses from the pool. The fuel pool is an unlined, single wall, reinforced concrete structure containing approximately 818,000 gallons of water.Since an initial test indicated that water losses could possibly be attributed solely to evaporation, a cover was suspended and sealed over the pool to block evaporation losses. High accuracy water level and temperature instrumentation was procured and installed. The conclusions of this report indicate that unaccounted-for water losses from the pool are insignificant and there is no detectable leakage within the range of test accuracy.