EXPECTED PRECISION OF NEUTRON MULTIPLICITY MEASUREMENTS OF WASTE DRUMS

Year
1995
Author(s)
H.O. Menlove - Los Alamos National Laboratory
N. Ensslin - Los Alamos National Laboratory
M. S. Krick - Los Alamos National Laboratory
Abstract
DOE facilities are beginning to apply passive neutron multiplicity counting techniques to the assay of plutonium scrap and residues. There is also considerable interest in applying this new measurement technique to 208-liter waste drums. The additional information available from multiplicity counting could flag the presence of shielding materials or improve assay accuracy by correcting for matrix effects such as (&#945,n) induced fission or detector efficiency variations. The potential for multiplicity analysis of waste drums, and the importance of better detector design, can be estimated by calculating the expected assay precision using a Figure of Merit code for assay variance. This paper reports results obtained as a function of waste drum content and detector characteristics. We find that multiplicity analysis of waste drums is feasible if a high-efficiency neutron counter is used. However, results are significantly poorer if the multiplicity analysis must be used to solve for detection efficiency.